CDS33-N Series UPS
- The world’s highest density power solution
- 40kVA UPS module capacity
- Double Conversion with capability for switching to Multi-Mode
- (Automatically switches between Double Conversion and Line Interactive modes according to mains status if Multi-Mode is activated)
- Designed for standard 19” rack
- Unlimited parallel expansion capability
- 3-Level intelligent charging mode
- Wide ranges of input voltage and input frequency
- Excellent generator compatibility
- 3-Phase input, 3-Phase output
- Separated AC input for rectifier and bypass
- Rack standalone UPS module
- Separated bypass for module
- Shared or separated batteries in parallel configuration (selectable)
- Selectable external battery quantity (384Vdc up to 480Vdc)
- Adjustable charging current
- Advanced battery management
- Optional Emergency Power Off function (EPO)
- On-grid capability for testing UPS in 100% load without real full loads
Technical Specifications
General |
|||
UPS Model | CDS33-N40 | ||
Rated apparent power | 40 kVA | ||
Applicable standard |
IEC62040-3 | ||
UPS classification | VFI SS CCC*
*C: 1 or 2 or 3 by order refer to IEC 62040-3 |
||
UPS topology |
Double Conversion / Multi-Mode
(selectable by user) |
||
Efficiency | 96% | ||
Parallel expansion capability |
Unlimited | ||
N+1 redundancy capability | Yes | ||
Dimensions | 203.5(4.5U) × 449 × 637mm | ||
Weight | 59Kg | ||
Acoustic noise at 1m |
≤58dBA | ||
Degree of protection against hazards and water ingress | IP20 | ||
Mean Time Between Failures (MTBF) |
250,000h | ||
Environmental |
|||
Operating temperature |
0°C to +40°C | ||
Storage temperature | -25°C to +55°C | ||
Humidity |
0 to 95% non-condensing | ||
Altitude at rated power
0.974 × rated power 0.920 × rated power 0.872 × rated power 0.820 × rated power |
≤1500m
≤2000m ≤3000m ≤4000m ≤5000m |
||
Input |
|||
Phases required |
3Ph+N+PE | ||
Rated voltage | 400Vac | ||
Voltage tolerance 100% load 70% load 50% load |
±20% -30% to +20% -48% to +20% |
||
Frequency range | 35Hz to 70Hz | ||
Power factor |
≥0.99 | ||
THDi | ≤3% | ||
Bypass voltage range max. voltage min. voltage |
400Vac +10% 400Vac -20% (optional -10%) |
||
Output |
|||
Output phases available |
3Ph+N+PE | ||
Rated voltage |
400Vac | ||
Voltage regulation
double conversion mode stored energy mode |
±1% ±1% |
||
Power factor |
0.9 | ||
Frequency
double conversion mode stored energy mode |
50/60Hz ±10% (adj.) 50/60Hz ±0.1% |
||
Crest factor |
3:1 | ||
THD
linear load nonlinear load |
≤2% ≤3% |
||
Transfer time double conversion mode to stored energy mode double conversion mode to bypass |
0.00Sec 0.00Sec |
||
Overload double conversion mode
up to110% >110% up to 125% >125% up to 150% >150% energy saving mode |
60min 10min 1min transfer to bypass |
||
according to bypass breaker curve | |||
Battery |
|||
Battery type |
All types of lead acid and gel, sealed or vented | ||
Normal voltage |
384Vdc up to 480Vdc (selectable) | ||
Max. charge current per module |
10A per module (10A per 40kVA power) | ||
Protections |
|||
Short circuit |
|||
Overload |
|||
Output overvoltage |
|||
Overheat |
|||
Battery low |
|||
Battery reverse (optional) |
|||
Self-diagnostics |
|||
EPO (optional) |
|||
Display |
|||
UPS module |
Audible & visual |
Mains Failure, Low Battery, Overload, System Fault | |
Status LED & LCD |
Double Conversion Mode, Energy Saving Mode, Low Battery,
Battery Test Failure, Overload, UPS Fault |
||
LCD information |
Input Voltage, Input Frequency, Output Voltage, Output Frequency,
Load Percentage, Battery Voltage, Parameters Set., History Record |
||
Communication Interface |
|||
USB, RS485, Dry contacts (optional), SNMP card (optional), Relay card (optional), Parallel port |