- 1,2,3 and 4-Pole miniature circuit breaker
- Wide current range: 6 to 63A
- Indicating state and tripping
- Compliance with standards: IEC 60898, IEC 60947-2
- Wide choice of breaking capacity and tripping current
- Breaking capacity of CM11 series: 3KA (IEC 60898), 4.5KA (IEC 60947-2)
Technical Specifications
|
Number of poles |
1 | 2 | 3 | 3+N | ||||
| Rated operational voltage |
Vac | 230/400 | 400 | |||||
| Rated Current |
A | 6 – 10 – 16 – 20 – 25 – 32 – 40 – 50 – 63 | ||||||
| Rated frequency |
Hz | 50/60 | ||||||
|
Range of instantaneous tripping current |
B-type1 – C-type2 – D-type3 | |||||||
| Tripping type |
Thermal magnetic |
|||||||
|
Rated short circuit capacity |
A | 3000 (IEC 60898), 4500 (IEC 60947-2) | ||||||
|
Temperature coefficient for thermal tripping |
% | +0.5%/-0.5% per 1°C less/more than 30 °C for B-type and C-type |
||||||
| +0.5%/-0.5% per 1°C less/more than 40 °C for D-type |
||||||||
|
Impulse withstand voltage |
KV | 4 | ||||||
|
Operating cycle |
20000 | |||||||
|
Protection against external influence |
|
Enclosed type | ||||||
| Method of mounting |
35 mm DIN rail |
|||||||
|
Method of connection |
Screw type | |||||||
| Width | mm | 18 | 36 | 54 | 72 | |||
|
Depth |
mm |
73 | ||||||
|
Height |
mm | 77 | ||||||
|
Degree of protection |
IP | IP 20 |
||||||
|
Pollution level |
3 | |||||||
|
Ambient temperature |
°C | -40 to +80 | ||||||
|
Relative humidity |
% | ≤95 | ||||||
|
Altitude |
m | ≤2000 | ||||||
- 1Above 3 In up to and including 5 In at 30 °C for magnetic tripping according to IEC 60898
- 2Above 5 In up to and including 10 In at 30 °C for magnetic tripping according to IEC 60898
- 3Above 10 In up to and including 14 In at 40 °C for magnetic tripping according to IEC 60947-2
CM11 Series Model Numbers
| 1-Pole | Rated Current (A) | Type B | Type C | Type D |
| 6 | CM11-B6/1 | CM11-C6/1 |
CM11-D6/1 |
|
| 10 | CM11-B10/1 | CM11-C10/1 | CM11-D10/1 | |
| 16 | CM11-B16/1 |
CM11-C16/1 |
CM11-D16/1 |
|
| 20 | CM11-B20/1 | CM11-C20/1 | CM11-D20/1 | |
| 25 | CM11-B25/1 | CM11-C25/1 | CM11-D25/1 | |
| 32 | CM11-B32/1 | CM11-C32/1 | CM11-D32/1 | |
| 40 | CM11-B40/1 | CM11-C40/1 | CM11-D40/1 | |
| 50 | CM11-B50/1 | CM11-C50/1 | CM11-D50/1 | |
| 63 | CM11-B63/1 | CM11-C63/1 | CM11-D63/1 | |
| 2-Pole | 6 | CM11-B6/2 | CM11-C6/2 | CM11-D6/2 |
| 10 | CM11-B10/2 | CM11-C10/2 | CM11-D10/2 | |
| 16 | CM11-B16/2 | CM11-C16/2 | CM11-D16/2 | |
| 20 | CM11-B20/2 | CM11-C20/2 | CM11-D20/2 | |
| 25 | CM11-B25/2 | CM11-C25/2 | CM11-D25/2 | |
| 32 | CM11-B32/2 | CM11-C32/2 | CM11-D32/2 | |
| 40 | CM11-B40/2 | CM11-C40/2 | CM11-D40/2 | |
| 50 | CM11-B50/2 | CM11-C50/2 | CM11-D50/2 | |
| 63 | CM11-B63/2 | CM11-C63/2 | CM11-D63/2 | |
| 3-Pole | 6 | CM11-B6/3 | CM11-C6/3 | CM11-D6/3 |
| 10 | CM11-B10/3 | CM11-C10/3 | CM11-D10/3 | |
| 16 | CM11-B16/3 | CM11-C16/3 | CM11-D16/3 | |
| 20 | CM11-B20/3 | CM11-C20/3 | CM11-D20/3 | |
| 25 | CM11-B25/3 | CM11-C25/3 | CM11-D25/3 | |
| 32 | CM11-B32/3 | CM11-C32/3 | CM11-D32/3 | |
| 40 | CM11-B40/3 | CM11-C40/3 | CM11-D40/3 | |
| 50 | CM11-B50/3 | CM11-C50/3 | CM11-D50/3 | |
| 63 | CM11-B63/3 | CM11-C63/3 | CM11-D63/3 | |
| 4-Pole | 6 | CM11-B6/4 | CM11-C6/4 | CM11-D6/4 |
| 10 | CM11-B10/4 | CM11-C10/4 | CM11-D10/4 | |
| 16 | CM11-B16/4 | CM11-C16/4 | CM11-D16/4 | |
| 20 | CM11-B20/4 | CM11-C20/4 | CM11-D20/4 | |
| 25 | CM11-B25/4 | CM11-C25/4 | CM11-D25/4 | |
| 32 | CM11-B32/4 | CM11-C32/4 | CM11-D32/4 | |
| 40 | CM11-B40/4 | CM11-C40/4 | CM11-D40/4 | |
| 50 | CM11-B50/4 | CM11-C50/4 | CM11-D50/4 | |
| 63 | CM11-B63/4 | CM11-C63/4 | CM11-D63/4 |
- 1,2,3 and 4-Pole miniature circuit breaker
- Wide current range: 6 to 63A
- Indicating state and tripping
- Compliance with standards: IEC 60898, IEC 60947-2
- Wide choice of breaking capacity and tripping current
- Breaking capacity of CM12 series: 4.5KA (IEC 60898), 6KA (IEC 60947-2)
Technical Specifications
|
Number of poles |
1 | 2 | 3 | 3+N | ||||
| Rated operational voltage |
Vac | 230/400 | 400 | |||||
| Rated Current |
A | 6 – 10 – 16 – 20 – 25 – 32 – 40 – 50 – 63 | ||||||
| Rated frequency |
Hz | 50/60 | ||||||
|
Range of instantaneous tripping current |
B-type1 – C-type2 – D-type3 | |||||||
| Tripping type |
Thermal magnetic |
|||||||
|
Rated short circuit capacity |
A | 45000 (IEC 60898), 6000 (IEC 60947-2) | ||||||
|
Temperature coefficient for thermal tripping |
% | +0.5%/-0.5% per 1°C less/more than 30 °C for B-type and C-type |
||||||
| +0.5%/-0.5% per 1°C less/more than 40 °C for D-type |
||||||||
|
Impulse withstand voltage |
KV | 4 | ||||||
|
Operating cycle |
20000 | |||||||
|
Protection against external influence |
|
Enclosed type | ||||||
| Method of mounting |
35 mm DIN rail |
|||||||
|
Method of connection |
Screw type | |||||||
| Width | mm | 18 | 36 | 54 | 72 | |||
|
Depth |
mm |
73 | ||||||
|
Height |
mm | 77 | ||||||
|
Degree of protection |
IP | IP 20 |
||||||
|
Pollution level |
3 | |||||||
|
Ambient temperature |
°C | -40 to +80 | ||||||
|
Relative humidity |
% | ≤95 | ||||||
|
Altitude |
m | ≤2000 | ||||||
- 1Above 3 In up to and including 5 In at 30 °C for magnetic tripping according to IEC 60898
- 2Above 5 In up to and including 10 In at 30 °C for magnetic tripping according to IEC 60898
- 3Above 10 In up to and including 14 In at 40 °C for magnetic tripping according to IEC 60947-2
CM12 Series Model Numbers
| 1-Pole | Rated Current (A) | Type B | Type C | Type D |
| 6 | CM12-B6/1 | CM12-C6/1 |
CM12-D6/1 |
|
| 10 | CM12-B10/1 | CM12-C10/1 | CM12-D10/1 | |
| 16 | CM12-B16/1 |
CM12-C16/1 |
CM12-D16/1 |
|
| 20 | CM12-B20/1 | CM12-C20/1 | CM12-D20/1 | |
| 25 | CM12-B25/1 | CM12-C25/1 | CM12-D25/1 | |
| 32 | CM12-B32/1 | CM12-C32/1 | CM12-D32/1 | |
| 40 | CM12-B40/1 | CM12-C40/1 | CM12-D40/1 | |
| 50 | CM12-B50/1 | CM12-C50/1 | CM12-D50/1 | |
| 63 | CM12-B63/1 | CM12-C63/1 | CM12-D63/1 | |
| 2-Pole | 6 | CM12-B6/2 | CM12-C6/2 | CM12-D6/2 |
| 10 | CM12-B10/2 | CM12-C10/2 | CM12-D10/2 | |
| 16 | CM12-B16/2 | CM12-C16/2 | CM12-D16/2 | |
| 20 | CM12-B20/2 | CM12-C20/2 | CM12-D20/2 | |
| 25 | CM12-B25/2 | CM12-C25/2 | CM12-D25/2 | |
| 32 | CM12-B32/2 | CM12-C32/2 | CM12-D32/2 | |
| 40 | CM12-B40/2 | CM12-C40/2 | CM12-D40/2 | |
| 50 | CM12-B50/2 | CM12-C50/2 | CM12-D50/2 | |
| 63 | CM12-B63/2 | CM12-C63/2 | CM12-D63/2 | |
| 3-Pole | 6 | CM12-B6/3 | CM12-C6/3 | CM12-D6/3 |
| 10 | CM12-B10/3 | CM12-C10/3 | CM12-D10/3 | |
| 16 | CM12-B16/3 | CM12-C16/3 | CM12-D16/3 | |
| 20 | CM12-B20/3 | CM12-C20/3 | CM12-D20/3 | |
| 25 | CM12-B25/3 | CM12-C25/3 | CM12-D25/3 | |
| 32 | CM12-B32/3 | CM12-C32/3 | CM12-D32/3 | |
| 40 | CM12-B40/3 | CM12-C40/3 | CM12-D40/3 | |
| 50 | CM12-B50/3 | CM12-C50/3 | CM12-D50/3 | |
| 63 | CM12-B63/3 | CM12-C63/3 | CM12-D63/3 | |
| 4-Pole | 6 | CM12-B6/4 | CM12-C6/4 | CM12-D6/4 |
| 10 | CM12-B10/4 | CM12-C10/4 | CM12-D10/4 | |
| 16 | CM12-B16/4 | CM12-C16/4 | CM12-D16/4 | |
| 20 | CM12-B20/4 | CM12-C20/4 | CM12-D20/4 | |
| 25 | CM12-B25/4 | CM12-C25/4 | CM12-D25/4 | |
| 32 | CM12-B32/4 | CM12-C32/4 | CM12-D32/4 | |
| 40 | CM12-B40/4 | CM12-C40/4 | CM12-D40/4 | |
| 50 | CM12-B50/4 | CM12-C50/4 | CM12-D50/4 | |
| 63 | CM12-B63/4 | CM12-C63/4 | CM12-D63/4 |
- 1,2,3 and 4-Pole miniature circuit breaker
- Wide current range: 6 to 63A
- Indicating state and tripping
- Compliance with standards: IEC 60898, IEC 60947-2
- Wide choice of breaking capacity and tripping current
- Breaking capacity of CM13 series: 6KA (IEC 60898), 10KA (IEC 60947-2)
Technical Specifications
|
Number of poles |
1 | 2 | 3 | 3+N | ||||
| Rated operational voltage |
Vac | 230/400 | 400 | |||||
| Rated Current |
A | 6 – 10 – 16 – 20 – 25 – 32 – 40 – 50 – 63 | ||||||
| Rated frequency |
Hz | 50/60 | ||||||
|
Range of instantaneous tripping current |
B-type1 – C-type2 – D-type3 | |||||||
| Tripping type |
Thermal magnetic |
|||||||
|
Rated short circuit capacity |
A | 6000 (IEC 60898), 10000 (IEC 60947-2) | ||||||
|
Temperature coefficient for thermal tripping |
% | +0.5%/-0.5% per 1°C less/more than 30 °C for B-type and C-type |
||||||
| +0.5%/-0.5% per 1°C less/more than 40 °C for D-type |
||||||||
|
Impulse withstand voltage |
KV | 4 | ||||||
|
Operating cycle |
20000 | |||||||
|
Protection against external influence |
|
Enclosed type | ||||||
| Method of mounting |
35 mm DIN rail |
|||||||
|
Method of connection |
Screw type | |||||||
| Width | mm | 18 | 36 | 54 | 72 | |||
|
Depth |
mm |
73 | ||||||
|
Height |
mm | 77 | ||||||
|
Degree of protection |
IP | IP 20 |
||||||
|
Pollution level |
3 | |||||||
|
Ambient temperature |
°C | -40 to +80 | ||||||
|
Relative humidity |
% | ≤95 | ||||||
|
Altitude |
m | ≤2000 | ||||||
- 1Above 3 In up to and including 5 In at 30 °C for magnetic tripping according to IEC 60898
- 2Above 5 In up to and including 10 In at 30 °C for magnetic tripping according to IEC 60898
- 3Above 10 In up to and including 14 In at 40 °C for magnetic tripping according to IEC 60947-2
CM13 Series Model Numbers
| 1-Pole | Rated Current (A) | Type B | Type C | Type D |
| 6 | CM13-B6/1 | CM13-C6/1 |
CM13-D6/1 |
|
| 10 | CM13-B10/1 | CM13-C10/1 | CM13-D10/1 | |
| 16 | CM13-B16/1 |
CM13-C16/1 |
CM13-D16/1 |
|
| 20 | CM13-B20/1 | CM13-C20/1 | CM13-D20/1 | |
| 25 | CM13-B25/1 | CM13-C25/1 | CM13-D25/1 | |
| 32 | CM13-B32/1 | CM13-C32/1 | CM13-D32/1 | |
| 40 | CM13-B40/1 | CM13-C40/1 | CM13-D40/1 | |
| 50 | CM13-B50/1 | CM13-C50/1 | CM13-D50/1 | |
| 63 | CM13-B63/1 | CM13-C63/1 | CM13-D63/1 | |
| 2-Pole | 6 | CM13-B6/2 | CM13-C6/2 | CM13-D6/2 |
| 10 | CM13-B10/2 | CM13-C10/2 | CM13-D10/2 | |
| 16 | CM13-B16/2 | CM13-C16/2 | CM13-D16/2 | |
| 20 | CM13-B20/2 | CM13-C20/2 | CM13-D20/2 | |
| 25 | CM13-B25/2 | CM13-C25/2 | CM13-D25/2 | |
| 32 | CM13-B32/2 | CM13-C32/2 | CM13-D32/2 | |
| 40 | CM13-B40/2 | CM13-C40/2 | CM13-D40/2 | |
| 50 | CM13-B50/2 | CM13-C50/2 | CM13-D50/2 | |
| 63 | CM13-B63/2 | CM13-C63/2 | CM13-D63/2 | |
| 3-Pole | 6 | CM13-B6/3 | CM13-C6/3 | CM13-D6/3 |
| 10 | CM13-B10/3 | CM13-C10/3 | CM13-D10/3 | |
| 16 | CM13-B16/3 | CM13-C16/3 | CM13-D16/3 | |
| 20 | CM13-B20/3 | CM13-C20/3 | CM13-D20/3 | |
| 25 | CM13-B25/3 | CM13-C25/3 | CM13-D25/3 | |
| 32 | CM13-B32/3 | CM13-C32/3 | CM13-D32/3 | |
| 40 | CM13-B40/3 | CM13-C40/3 | CM13-D40/3 | |
| 50 | CM13-B50/3 | CM13-C50/3 | CM13-D50/3 | |
| 63 | CM13-B63/3 | CM13-C63/3 | CM13-D63/3 | |
| 4-Pole | 6 | CM13-B6/4 | CM13-C6/4 | CM13-D6/4 |
| 10 | CM13-B10/4 | CM13-C10/4 | CM13-D10/4 | |
| 16 | CM13-B16/4 | CM13-C16/4 | CM13-D16/4 | |
| 20 | CM13-B20/4 | CM13-C20/4 | CM13-D20/4 | |
| 25 | CM13-B25/4 | CM13-C25/4 | CM13-D25/4 | |
| 32 | CM13-B32/4 | CM13-C32/4 | CM13-D32/4 | |
| 40 | CM13-B40/4 | CM13-C40/4 | CM13-D40/4 | |
| 50 | CM13-B50/4 | CM13-C50/4 | CM13-D50/4 | |
| 63 | CM13-B63/4 | CM13-C63/4 | CM13-D63/4 |
- 1,2,3 and 4-Pole miniature circuit breaker
- Wide current range: 6 to 63A
- Indicating state and tripping
- Compliance with standards: IEC 60898, IEC 60947-2
- Wide choice of breaking capacity and tripping current
- Breaking capacity of CM14 series: 10KA (IEC 60898), 15KA (IEC 60947-2)
Technical Specifications
|
Number of poles |
1 | 2 | 3 | 3+N | ||||
| Rated operational voltage |
Vac | 230/400 | 400 | |||||
| Rated Current |
A | 6 – 10 – 16 – 20 – 25 – 32 – 40 – 50 – 63 | ||||||
| Rated frequency |
Hz | 50/60 | ||||||
|
Range of instantaneous tripping current |
B-type1 – C-type2 – D-type3 | |||||||
| Tripping type |
Thermal magnetic |
|||||||
|
Rated short circuit capacity |
A | 10000 (IEC 60898), 15000 (IEC 60947-2) | ||||||
|
Temperature coefficient for thermal tripping |
% | +0.5%/-0.5% per 1°C less/more than 30 °C for B-type and C-type |
||||||
| +0.5%/-0.5% per 1°C less/more than 40 °C for D-type |
||||||||
|
Impulse withstand voltage |
KV | 4 | ||||||
|
Operating cycle |
20000 | |||||||
|
Protection against external influence |
|
Enclosed type | ||||||
| Method of mounting |
35 mm DIN rail |
|||||||
|
Method of connection |
Screw type | |||||||
| Width | mm | 18 | 36 | 54 | 72 | |||
|
Depth |
mm |
73 | ||||||
|
Height |
mm | 81 | ||||||
|
Degree of protection |
IP | IP 20 |
||||||
|
Pollution level |
3 | |||||||
|
Ambient temperature |
°C | -40 to +80 | ||||||
|
Relative humidity |
% | ≤95 | ||||||
|
Altitude |
m | ≤2000 | ||||||
- 1Above 3 In up to and including 5 In at 30 °C for magnetic tripping according to IEC 60898
- 2Above 5 In up to and including 10 In at 30 °C for magnetic tripping according to IEC 60898
- 3Above 10 In up to and including 14 In at 40 °C for magnetic tripping according to IEC 60947-2
CM14 Series Model Numbers
| 1-Pole | Rated Current (A) | Type B | Type C | Type D |
| 6 | CM14-B6/1 | CM14-C6/1 |
CM14-D6/1 |
|
| 10 | CM14-B10/1 | CM14-C10/1 | CM14-D10/1 | |
| 16 | CM14-B16/1 |
CM14-C16/1 |
CM14-D16/1 |
|
| 20 | CM14-B20/1 | CM14-C20/1 | CM14-D20/1 | |
| 25 | CM14-B25/1 | CM14-C25/1 | CM14-D25/1 | |
| 32 | CM14-B32/1 | CM14-C32/1 | CM14-D32/1 | |
| 40 | CM14-B40/1 | CM14-C40/1 | CM14-D40/1 | |
| 50 | CM14-B50/1 | CM14-C50/1 | CM14-D50/1 | |
| 63 | CM14-B63/1 | CM14-C63/1 | CM14-D63/1 | |
| 2-Pole | 6 | CM14-B6/2 | CM14-C6/2 | CM14-D6/2 |
| 10 | CM14-B10/2 | CM14-C10/2 | CM14-D10/2 | |
| 16 | CM14-B16/2 | CM14-C16/2 | CM14-D16/2 | |
| 20 | CM14-B20/2 | CM14-C20/2 | CM14-D20/2 | |
| 25 | CM14-B25/2 | CM14-C25/2 | CM14-D25/2 | |
| 32 | CM14-B32/2 | CM14-C32/2 | CM14-D32/2 | |
| 40 | CM14-B40/2 | CM14-C40/2 | CM14-D40/2 | |
| 50 | CM14-B50/2 | CM14-C50/2 | CM14-D50/2 | |
| 63 | CM14-B63/2 | CM14-C63/2 | CM14-D63/2 | |
| 3-Pole | 6 | CM14-B6/3 | CM14-C6/3 | CM14-D6/3 |
| 10 | CM14-B10/3 | CM14-C10/3 | CM14-D10/3 | |
| 16 | CM14-B16/3 | CM14-C16/3 | CM14-D16/3 | |
| 20 | CM14-B20/3 | CM14-C20/3 | CM14-D20/3 | |
| 25 | CM14-B25/3 | CM14-C25/3 | CM14-D25/3 | |
| 32 | CM14-B32/3 | CM14-C32/3 | CM14-D32/3 | |
| 40 | CM14-B40/3 | CM14-C40/3 | CM14-D40/3 | |
| 50 | CM14-B50/3 | CM14-C50/3 | CM14-D50/3 | |
| 63 | CM14-B63/3 | CM14-C63/3 | CM14-D63/3 | |
| 4-Pole | 6 | CM14-B6/4 | CM14-C6/4 | CM14-D6/4 |
| 10 | CM14-B10/4 | CM14-C10/4 | CM14-D10/4 | |
| 16 | CM14-B16/4 | CM14-C16/4 | CM14-D16/4 | |
| 20 | CM14-B20/4 | CM14-C20/4 | CM14-D20/4 | |
| 25 | CM14-B25/4 | CM14-C25/4 | CM14-D25/4 | |
| 32 | CM14-B32/4 | CM14-C32/4 | CM14-D32/4 | |
| 40 | CM14-B40/4 | CM14-C40/4 | CM14-D40/4 | |
| 50 | CM14-B50/4 | CM14-C50/4 | CM14-D50/4 | |
| 63 | CM14-B63/4 | CM14-C63/4 | CM14-D63/4 |
- 1,2,3 and 4-Pole miniature circuit breaker
- Wide current range: 80 to 125A
- Indicating state and tripping
- Compliance with standards: IEC 60898, IEC 60947-2
- Wide choice of breaking capacity and tripping current
- Breaking capacity of CM15 series: 10KA (IEC 60898), 15KA (IEC 60947-2)
Technical Specifications
|
Number of poles |
1 | 2 | 3 | 3+N | ||||
| Rated operational voltage |
Vac | 230/400 | 400 | |||||
| Rated Current |
A | 80 – 100 – 125 | ||||||
| Rated frequency |
Hz | 50/60 | ||||||
|
Range of instantaneous tripping current |
B-type1 – C-type2 – D-type3 | |||||||
| Tripping type |
Thermal magnetic |
|||||||
|
Rated short circuit capacity |
A | 10000 (IEC 60898), 15000 (IEC 60947-2) | ||||||
|
Temperature coefficient for thermal tripping |
% | +0.5%/-0.5% per 1°C less/more than 30 °C for B-type and C-type |
||||||
| +0.5%/-0.5% per 1°C less/more than 40 °C for D-type |
||||||||
|
Impulse withstand voltage |
KV | 4 | ||||||
|
Operating cycle |
20000 | |||||||
|
Protection against external influence |
|
Enclosed type | ||||||
| Method of mounting |
35 mm DIN rail |
|||||||
|
Method of connection |
Screw type | |||||||
| Width | mm | 27 | 54 | 81 | 108 | |||
|
Depth |
mm |
73 | ||||||
|
Height |
mm | 81 | ||||||
|
Degree of protection |
IP | IP 20 |
||||||
|
Pollution level |
3 | |||||||
|
Ambient temperature |
°C | -40 to +80 | ||||||
|
Relative humidity |
% | ≤95 | ||||||
|
Altitude |
m | ≤2000 | ||||||
- 1Above 3 In up to and including 5 In at 30 °C for magnetic tripping according to IEC 60898
- 2Above 5 In up to and including 10 In at 30 °C for magnetic tripping according to IEC 60898
- 3Above 10 In up to and including 14 In at 40 °C for magnetic tripping according to IEC 60947-2
CM15 Series Model Numbers
| 1-Pole | Rated Current (A) | Type B | Type C | Type D |
| 80 | CM15-B80/1 | CM15-C80/1 |
CM15-D80/1 |
|
| 100 | CM15-B100/1 | CM15-C100/1 | CM15-D100/1 | |
| 125 | CM15-B125/1 |
CM15-C125/1 |
CM15-D125/1 |
|
| 2-Pole | 80 | CM15-B80/2 | CM15-C80/2 | CM15-D80/2 |
| 100 | CM15-B100/2 | CM15-C100/2 | CM15-D100/2 | |
| 125 | CM15-B125/2 | CM15-C125/2 | CM15-D125/2 | |
| 3-Pole | 80 | CM15-B80/3 | CM15-C80/3 | CM15-D80/3 |
| 100 | CM15-B100/3 | CM15-C100/3 | CM15-D100/3 | |
| 125 | CM15-B125/3 | CM15-C125/3 | CM15-D125/3 | |
| 4-Pole | 80 | CM15-B80/4 | CM15-C80/4 | CM15-D80/4 |
| 100 | CM15-B100/4 | CM15-C100/4 | CM15-D100/4 | |
| 125 | CM15-B125/4 | CM15-C125/4 | CM15-D125/4 |